POWERSCAN™ D8330/M8300 iv 6.2.5 Setting RTC ...
88 DECODING PARAMETERS Ink Spread Overflow Control Interdigit Control Decoding Safety Puzzle Solver™ Before changing these paramet
Enter Configuration Exit and Save Ì$+;Î DECODING PARAMETERS Ì$-?Î 89 INK SPREAD disable ÌAX0{Î enable ÌAX1~Î See section 5.7.1 for details.
Enter Configuration Exit and Save Ì$+;Î DECODING PARAMETERS Ì$-?Î 90 DECODING SAFETY one read ÌED0WÎ (decoding safety disabled) two reads
91 CODE SELECTION Auto-configuration EAN/UPC Family 2/5 Family Code 39 Family Code 128 Family Codabar Family Code 93 MSI Code 11
92 Code selections may be performed according to two different procedures: - Auto-configuration, allowing an automatic recognition and selection o
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 93 DISABLE ALL CODE FAMILIES ÌAZ0ÃÎ The reader allows up to 10 code selections. T
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 94 EAN/UPC FAMILY disable the family ÌAA0MÎ Read the desired family code NOTE
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 95 WITH ADD ON 2 ONLY EAN 8/EAN 13 ÌAAK7Î UPC A/UPC E ÌAAM=Î WITH ADD ON 5 ONLY
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 96 SELECT EAN/UPC PREFIXES When scanning the following codes, barcodes starting wi
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 97 Example: The following string allows reading and transmitting with ADD ON all EAN/U
GENERAL VIEW v GENERAL VIEW POWERSCAN™ D8330/M8300 READERS Figure A – PowerScan™ D8330/M8300 Series Reader Figure B – PowerScan™ M8300 Seri
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 98 EAN/UPC CHECK DIGIT TX SELECTIONS For each code type in this family you can choo
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 99 CONVERSION OPTIONS UPC E to UPC A conversion ÌAAAÄÎ UPC E to EAN 13 conversion
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 100 2/5 FAMILY disable the family ÌAC0QÎ Read the desired family code R
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 101 CODE 39 FAMILY disables the family ÌAB0OÎ Read the desired family code
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 102 CODE 128 FAMILY disable the family ÌAI0]Î Read the desired family code
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 103 CODE 93 disable the code ÌAK0aÎ Code 93 ÌAK1dÎ control without transmission
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 104 The Codabar ABC code below uses a fixed start/stop character transmission selec
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 105 MSI disable the family ÌAE0UÎ Enable the code by selecting one of the check di
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 106 CODE 11 disable the family ÌAG0YÎ Enable the code by selecting one of the ch
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 107 CODE 16K disable the code ÌAJ0_Î Code 16K ÌAJ1bÎ To read stacked codes, si
POWERSCAN™ D8330/M8300 vi BC-80X0 / C-8000 CRADLES Figure C – BC-8000 The label on the cradle contains LED indicators and a scan finder button. Wh
Enter Configuration Exit and Save Ì$+;Î CODE SELECTION Ì$-?Î 108 GS1 DATABAR™ CODES disable the family ÌAQ0mÎ DISABLE CODE disable GS1 DataB
109 ADVANCED FORMATTING NOT FOR PEN INTERFACES Concatenation Advanced Formatting Please follow the setup procedure carefully for these
Enter Configuration Exit and Save Ì$+;Î ADVANCED FORMATTING Ì$-?Î 110 CONCATENATION disable ÌEI0aÎ enable ÌEI1dÎ Permits the concatenati
Exit and Save ADVANCED FORMATTING Ì$-?Î 111 2 Code 2 code ID ÌEK1hÎ Read the code type from the Code Identifier Table beginning in Appen
Exit and Save ADVANCED FORMATTING Ì$-?Î 112 5 Transmission after Timeout no code transmitted after timeout ÌEM0iÎ only code 1 tran
ADVANCED FORMATTING 113 ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format of b
Enter Configuration Exit and Save Ì$+;Î ADVANCED FORMATTING Ì$-?Î 114 1 Begin Format Definition begin Format 1 definition ÌHA0TÎ be
Exit and Save ADVANCED FORMATTING Ì$-?Î 115 4 Match with Predefined Characters no match ÌHD0HE00ÄÎ OR match with 1 character ÌH
Exit and Save ADVANCED FORMATTING Ì$-?Î 116 5 Divide Code into Fields divide code into fields ÌHF.Î Read one number in the range 1
Exit and Save ADVANCED FORMATTING Ì$-?Î 117 DEFINE FIELD 1 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the HEX
INTRODUCTION 1 1 INTRODUCTION PowerScan™ D8330 and PowerScan™ M8300 offer unsurpassed robustness and ergonomics: clearly audible beeper and bri
Exit and Save ADVANCED FORMATTING Ì$-?Î 118 DEFINE FIELD 2 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the H
Exit and Save ADVANCED FORMATTING Ì$-?Î 119 DEFINE FIELD 3 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the HEX
Exit and Save ADVANCED FORMATTING Ì$-?Î 120 DEFINE FIELD 4 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the H
Exit and Save ADVANCED FORMATTING Ì$-?Î 121 DEFINE FIELD 5 BY: EITHER field separator a) ÌHG0`Î Read the field separator character from the HEX
Exit and Save ADVANCED FORMATTING Ì$-?Î 122 7 First Additional Fixed Field no fixed field ÌHI0dÎ 1 character fixed field ÌHI
Exit and Save ADVANCED FORMATTING Ì$-?Î 123 8 Second Additional Fixed Field no fixed field ÌHJ0fÎ 1 character fixed field ÌHJ1
Exit and Save ADVANCED FORMATTING Ì$-?Î 124 9 Field Transmission number of fields to transmit ÌHK8Î Read one number in the range 1
Exit and Save ADVANCED FORMATTING Ì$-?Î 125 10 Standard Formatting do not apply standard formatting ÌHL0jÎ apply stand
Enter Configuration Exit and Save Ì$+;Î ADVANCED FORMATTING Ì$-?Î 126 Enable Advanced Format no Advanced Formats enabled ÌHN0nÎ Advan
Enter Configuration Exit and Save Ì$+;Î ADVANCED FORMATTING Ì$-?Î 127 No Match Result clear data - no transmission ÌHO0pÎ transmit data using sta
POWERSCAN™ D8330/M8300 2 2 INSTALLATION Connections should always be made with power OFF! CAUTION 2.1 POWERSCAN™ D8330 INTERFACE CABLE CONN
128 RADIO PARAMETERS PowerScan™ M8300 Series readers only Radio Protocol Timeout Radio RX Timeout Power-Off Timeout Transmission Mode
Enter Configuration Exit and Save Ì$+;Î RADIO PARAMETERS Ì$-?Î 129 RADIO PROTOCOL TIMEOUT radio protocol timeout ÌRH<Î Read a number from t
Enter Configuration Exit and Save Ì$+;Î RADIO PARAMETERS Ì$-?Î 130 POWER-OFF TIMEOUT power-off timeout ÌRPLÎ Read 2 numbers in the range 00-99
Enter Configuration Exit and Save Ì$+;Î RADIO PARAMETERS Ì$-?Î 131 BEEPER CONTROL FOR RADIO RESPONSE normal ÌBF0XÎ only good decode on
Enter Configuration Exit and Save Ì$+;Î RADIO PARAMETERS Ì$-?Î 132 SINGLE STORE disable ÌRO0zÎ one attempt two attempts ÌRO1}Î ÌRO2ÄÎ
Enter Configuration Exit and Save Ì$+;Î RADIO PARAMETERS Ì$-?Î 133 BATCH MODE disable batch ÌBZ0ÄÎ enable automatic batch enable normal
134 DISPLAY AND KEYPAD PARAMETERS PowerScan™ M8300 Series Display and 3-Key readers only Date and Time Contrast Font Size Backlight
Enter Configuration Exit and Save Ì$+;Î DISPLAY PARAMETERS Ì$-?Î 135 DISPLAY PARAMETERS DATE AND TIME set date ÌIA%Î set time Read 6 nu
Enter Configuration Exit and Save Ì$+;Î KEYPAD PARAMETERS Ì$-?Î 136 DISPLAY-OFF TIMEOUT timeout ÌIF/Î Read 2 numbers in the range 00-99: 00 = d
Enter Configuration Exit and Save Ì$+;Î DISPLAY PARAMETERS Ì$-?Î 137 KEYPAD disable 3-key keypad ÌIK0iÎ enable 3-key keypad and select ch
INSTALLATION 3 Follow the given procedure for correct cable insertion: Slip the cover over the cable. Push the plastic boot into the rubbe
POWERSCAN™ D8330/M8300 138 5 REFERENCES 5.1 RS-232 PARAMETERS 5.1.1 Handshaking Hardware handshaking: (RTS/CTS) The RTS line is activated by
REFERENCES 139 5.1.2 ACK/NACK Protocol PowerScan™ D8330 Readers This parameter sets a transmission protocol in which the Host responds to the reade
POWERSCAN™ D8330/M8300 140 BC-80X0 Host datacable PowerScan® M8300 data NACK ACKgood RX beep Transmission Mode = Two-Waysdata ACK/NACK enabled
REFERENCES 141 5.1.4 RX Timeout When the RS-232 interface is selected, the Host can be used to configure the device by sending it command strings (
POWERSCAN™ D8330/M8300 142 5.2.3 Overflow This parameter generates a white space before the first bar and after the last bar of the code. The selec
REFERENCES 143 5.2.5 Inter-Block Delay For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20 characters each. The i
POWERSCAN™ D8330/M8300 144 The message is sent in the following format: "Message" CR LF 5.3.3 Reception Warning Message The Master cra
REFERENCES 145 5.4 DATA FORMAT For an overview of Message Formatting see Chapter 6. 5.4.1 Header/Terminator Selection The header/terminator sele
Enter Configuration Exit and Save Ì$+;Î Ì$-?Î 146 5.4.2 Define Special Key Sequence The Special Key(s) for Wedge IBM AT-PS/2 and USB-KBD interfa
REFERENCES 147 2. Read only one code to be associated with the special key sequence: SHIFT Ì12Î OR CTRL Ì23Î OR ALT Ì45Î
POWERSCAN™ D8330/M8300 4 2.2 BC-80X0 INTERFACE CABLE CONNECTIONS BC-80X0 Connectors The BC-80X0 incorporates a multi-standard interface, whi
POWERSCAN™ D8330/M8300 148 3. Select the character to be associated with the Special Key sequence by reading the codes corresponding to the 3 charac
REFERENCES 149 ITA USA FR BE DE UK ES SW JP : 049 S 04C S049 049 049 S04C S049 S049 S 052 ; 041 S 04C 041 041 041 S04C 041 S041 S 04C < 061
POWERSCAN™ D8330/M8300 150 ITA USA FR BE DE UK ES SW JP w 01D 01D 01A 01A 01D 01D 01D 01D 01D x 022 022 022 022 022 022 022 022 022 y 035 035
REFERENCES 151 ITA USA FR BE DE UK ES SW JP Up arrow 275 275 275 275 275 275 275 275 275 Down arrow 272 272 272 272 272 272 272 272 272 Left
POWERSCAN™ D8330/M8300 152 2. The following example allows defining Special Key 2 as CTRL + S (uppercase): enter configuration define Special
REFERENCES 153 - Integrating Special Keys in Headers/Terminators - 1. The following example allows setting Special Key 1 (defined in example 1 abo
POWERSCAN™ D8330/M8300 154 5.4.3 Address Stamping It is possible to include the reader address in the message sent to the host. The Reader Address
REFERENCES 155 5.5 POWER SAVE 5.5.1 Sleep State When using interfaces other than USB, this mode allows the P in the reader to enter a “Sleep” s
POWERSCAN™ D8330/M8300 156 5.6 READING PARAMETERS 5.6.1 Trigger Signal This mode determines how the reading phase is controlled when the hardware
REFERENCES 157 In multiple reads per cycle, the ON period is extended so that the device can continue decoding codes until an OFF event occurs. For
INSTALLATION 5 2.3 RS-232 CONNECTION 2.4 USB (if required)
POWERSCAN™ D8330/M8300 158 5.7.3 Interdigit Control The interdigit control parameter verifies the interdigit spacing for code families Code 39 and
REFERENCES 159 5.9.2 Radio RX Timeout When the scanner is used in a standalone layout (point-to-point or with multiple readers) it can be configu
POWERSCAN™ D8330/M8300 160 5.9.4 Transmission Mode This parameter determines whether the reader receives responses or messages from the Host or not
REFERENCES 161 5.9.6 Single Store When single store mode is enabled, if the PowerScan™ M8300 fails to transmit a code to the cradle, it enters a s
POWERSCAN™ D8330/M8300 162 returns in range, transmission of the codes to the base station resumes automatically, according to the selected communica
REFERENCES 163 5.10 DISPLAY PARAMETERS (SOME M8300 MODELS ONLY) 5.10.1 Display Mode The user can control the reader display behavior according
POWERSCAN™ D8330/M8300 164 5.11 CONFIGURATION EDITING COMMANDS The following commands carry out their specific function and then exit the configura
REFERENCES 165 5.12 CUSTOM DEFAULT CONFIGURATION Read the following code to set the reader user-defined configuration as custom default configurat
POWERSCAN™ D8330/M8300 166 5.14 CONFIGURATION COPYING COMMANDS 5.14.1 Copy PowerScan D8330 Series Procedure: Connect the master (correctly con
REFERENCES 167 5.14.2 Copy PowerScan M8300 Series Procedure: Using the slave reader and its BC-80X0 cradle, follow the initialization procedure
POWERSCAN™ D8330/M8300 6 2.5 IBM USB POS (if required)
POWERSCAN™ D8330/M8300 168 5.14.3 Copy BC-80X0 Procedure: Using the slave reader and its BC-80X0 cradle, read the Restore Default barcode, set th
REFERENCES 169 5.15 DEFAULT PARAMETERS FOR POS TERMINALS The default values of the RS-232 and Data Format parameters for POS terminals are listed
POWERSCAN™ D8330/M8300 170 5.16 FIRMWARE UPGRADE Device firmware upgrades can be performed from your PC through either a USB or serial connection (
MESSAGE FORMATTING 171 6 MESSAGE FORMATTING 6.1 STANDARD MESSAGE FORMATTING The system always provides scanner to host data communication using
POWERSCAN™ D8330/M8300 172 6.2 MESSAGES FROM HOST TO READER The general format to enable the Scanner for a 2 way communication is: [Scanner_Addr]
MESSAGE FORMATTING 173 6.2.1 Cursor Control ESC [ n AUp n rows, no scrollESC [ n BDown n rows, no scrollESC [ n CRight n columnsESC [ n DLeft n co
POWERSCAN™ D8330/M8300 174 6.2.4 LED and Beeper Control ESC [ 0 q Emit short High tone + short delayESC [ 1 q Emit short Low tone + short delayES
MESSAGE FORMATTING 175 6.3 MESSAGES FROM SCANNER COMMAND KEYS 6.3.1 PowerScan M8300 keypad The PowerScan™ M8300 series scanners with display hav
POWERSCAN™ D8330/M8300 176 7 TECHNICAL FEATURES 7.1 POWERSCAN™ D8330 Electrical Features POWERSCAN™ D8330 POWERSCAN™ D8330 AR Power Supply 4 to
TECHNICAL FEATURES 177 7.2 POWERSCAN™ M8300 Electrical and General Features Battery Type 2150 Li-Ion battery pack Recharge Time max. 4 hours with
INSTALLATION 7 2.6 WEDGE CONNECTION 2.7 PEN EMULATION CONNECTION
POWERSCAN™ D8330/M8300 178 7.3 BC-80X0 / C-8000 Electrical and General Features Supply Voltage External Power 10 to 30 VDC Host Power 5 VDC
TECHNICAL FEATURES 179 7.4 SYSTEM AND RADIO FEATURES Radio Features European Models USA Models Radio Frequency 433.92 MHz 910 MHz Bit Rate 192
POWERSCAN™ D8330/M8300 180 POWERSCAN™ D8330/M8300 READER DATA ENTRY Beeper1 LED Good Read Spot Meaningone beep2 ON ON Correct read of a code in no
TECHNICAL FEATURES 181 BC-80X0/C-8000 POWER/COMMUNICATION Aux LED Host LED Meaning Yellow Yellow OFF OFF Device off ON Power applied through an
POWERSCAN™ D8330/M8300 182 7.6 Reading Tables POWERSCAN™ D8330/M8300 mil Typical reading distance with good quality codes 5 2.1 - 13.3 cm / 0.8
HOST CONFIGURATION STRINGS 183 A HOST CONFIGURATION STRINGS In this section we provide a description of how to modify the device configuration usin
POWERSCAN™ D8330/M8300 184 SERIAL CONFIGURATION STRINGS SPECIAL CONFIGURATION COMMANDS DESCRIPTION STRING Enter Configuration $+ Exit and Save Conf
HOST CONFIGURATION STRINGS 185 RS-232DESCRIPTION STRING Baud Rate 300 CD1 600 CD2 1200 CD3 2400 CD4 4800 CD5 9600 CD6 19200 CD7 38400
POWERSCAN™ D8330/M8300 186 USBDESCRIPTION STRING USB-COM Handshaking disable CE0 RTS/CTS CE1 XON/XOFF CE2 RTS always ON CE3 ACK/NACK Protoc
HOST CONFIGURATION STRINGS 187 WEDGEDESCRIPTION STRING Keyboard Nationality Belgian FJ7 English (UK) FJ4 French FJ2 German FJ3 Italian FJ1
© Copyright 2011 by Psion Inc.2100 Meadowvale BoulevardMississauga, Ontario, Canada L5N 7J9http://www.psion.comThis document and the information it co
POWERSCAN™ D8330/M8300 8 2.8 NETWORK CONNECTIONS 2.8.1 BC-8060 Network Connectors The multidrop network is a bus system which is propagated f
POWERSCAN™ D8330/M8300 188 PEN (continued)DESCRIPTION STRING Output Level normal DD0 inverted DD1 Idle Level normal DE0 inverted DE1 Overflo
HOST CONFIGURATION STRINGS 189 DATA FORMATNOT FOR PEN EMULATION INTERFACES DESCRIPTION STRING Code Identifier disable EB0 Manufacturer standard E
POWERSCAN™ D8330/M8300 190 DATA FORMAT (continued)NOT FOR PEN EMULATION INTERFACESDESCRIPTION STRING Code Length Tx not transmitted EE0 transmi
HOST CONFIGURATION STRINGS 191 POWER SAVEDESCRIPTION STRING Sleep State disable BQ0 (only for D8330 series) enable BQ1 Enter Sleep Timeout (10
POWERSCAN™ D8330/M8300 192 DECODING PARAMETERSDESCRIPTION STRING Ink-spread disable AX0 enable AX1 Overflow Control disable AW1 enable AW0 In
HOST CONFIGURATION STRINGS 193 CODE SELECTION (continued) DESCRIPTION STRING UPC A check digit transmission disable AAI0 enable AAI1 UPC
POWERSCAN™ D8330/M8300 194 CODE SELECTION (continued)DESCRIPTION STRING Codabar disable Codabar family AD0 Standard no start/stop character eq
HOST CONFIGURATION STRINGS 195 CODE SELECTION (continued)DESCRIPTION STRING Code 11 disable the family AG0 no check AG1 Type C with tx AG2
POWERSCAN™ D8330/M8300 196 DISPLAY PARAMETERSDESCRIPTION STRING Date IAddmmyy Time IBhhmm Contrast lighter IC0 darker IC1 Font Size small ID0
CODE IDENTIFIER TABLE 197 B CODE IDENTIFIER TABLE 2/5 Interleaved ÌNOÎ 2/5 Industrial 2/5 normal 5 bars ÌPQÎ ÌOPÎ 2/5 matrix 3 bars EAN 8 ÌQRÎ ÌA
INSTALLATION 9 2.8.2 Network Cabling The Multidrop line is made using RJ45 connectors and a cable having the following specifications: twisted
POWERSCAN™ D8330/M8300 198 UPC A with 5 ADD ON ÌGHÎ UPC E with 2 ADD ON UPC E with 5 ADD ON ÌHIÎ ÌIJÎ Code 39 Code 39 Full ASCII ÌVWÎ ÌWXÎ CODABAR AB
CODE IDENTIFIER TABLE 199 MSI ÌZ[Î Code 16K Code 11 ÌpqÎ ÌbcÎ Code 49 GS1 DATABAR Expanded Linear and Stacked ÌqrÎ ÌtuÎ GS1 DATABAR Limited GS1 DAT
POWERSCAN™ D8330/M8300 200 C HEX AND NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLEchar hex char hex char hex NUL 00 * 2A U 55 SOH 01 + 2
CODE IDENTIFIER TABLE 201 CHARACTER TO HEX CONVERSION TABLE (continued)char decimal hex char decimal hex char decimal hex € 128 80 ª 170 AA Õ 21
POWERSCAN™ D8330/M8300 202 HEX/NUMERIC BAR CODES 0 1 2 3 4 5 6 7 8 9
CODE IDENTIFIER TABLE 203 A B C D E F Backspace
NOTES
POWERSCAN™ D8330/M8300 10 2.8.3 Network Termination The first and last cradles of the chain (the two ends of the bus) must be properly terminate
INSTALLATION 11 2.9 POWERSCAN™ M8300 BATTERY MAINTENANCE 2.9.1 Battery Charging Once the system is connected and powered, you can place the Powe
POWERSCAN™ D8330/M8300 12 2.10 MOUNTING THE BC-80X0 / C-8000 CRADLE The cradle package contains the following items: BC-80X0 / C-8000 Cradle
INSTALLATION 13 2.10.1 Desktop Mounting For desktop usage, you can mount the cradle either on the horizontal base, for reduced overall dimensions,
POWERSCAN™ D8330/M8300 14 Portable Desktop Use 1. Correctly position the BC-80X0/C-8000 onto the base by sliding it along the mounting tabs unti
INSTALLATION 15 Horizontal Base Inclined Base 5. Remove the plastic from the other
POWERSCAN™ D8330/M8300 16 2.10.2 Wall Mounting 1. Remove the yellow caps and insert the two wall mounting lock hinges provided with your cradle
INSTALLATION 17 If using the adhesive strips: 3. Carefully clean the adhesive strip seats of the base to remove any impurities that could reduce a
Return to Factory WarrantyPsion provides a return to factory warranty on this product for aperiod of twelve (12) months in accordance with the stateme
POWERSCAN™ D8330/M8300 18 3 POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS There are two basic system layouts that can be employed: Stand-alone sys
POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS 19 3.1.3 Multiple Stand-Alone Layouts Many stand-alone connections can operate in the same physical a
POWERSCAN™ D8330/M8300 20 3.1.4 C-BOX Layout In this layout the BC-80X0 cradle is connected by a dedicated cable using the RS-232 interface t
POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS 21 3.2 MULTIDROP STAR-SYSTEM™ NETWORK LAYOUTS Even though many stand-alone systems can operate in the
POWERSCAN™ D8330/M8300 22 3.2.2 BC-8060 Master Layout A. Host B. BC-8060 Master cradleC. BC-8060 Slave cradlesD. STARGATE™ base stationExampl
POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS 23 3.2.3 Master BC-8060 Network Troubleshooting Two diagnostic strings can be sent via RS-232 from th
POWERSCAN™ D8330/M8300 24 4 CONFIGURATION 4.1 CONFIGURATION METHODS 4.1.1 Reading Configuration Barcodes This manual can be used for complete
CONFIGURATION 25 4.1.4 Sending Configuration Strings from Host An alternative configuration method is provided in Appendix A using the RS-232 inter
POWERSCAN™ D8330/M8300 26 4.3 POWERSCAN™ D8330 SETUP 1. Read the restore default parameters code below. Restore PowerScan™ D8330 Default Ì$+$*oÎ
CONFIGURATION 27 4.5 POWERSCAN™ M8300/BC-80X0 STAND-ALONE SETUP Read the restore default parameters code below. 1. Restore PowerScan™ M8300 Def
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC & Waste Batteries Directive 2006/66/ECThis Product, and its accessories, com
POWERSCAN™ D8330/M8300 28 7. Read the Bind code to pair the PowerScan™M8300 to the BC-80X0 cradle. The reader is dedicated to the cradle. Any previou
CONFIGURATION 29 4.5.1 Using Multiple M-Series Readers with the Same Cradle If you want to use several M-Series readers with the same BC-80X0 crad
POWERSCAN™ D8330/M8300 30 4.5.2 PowerScan™ M8300/STAR-Modem™ in Stand-Alone Mode To configure a PowerScan™ M8300 reader to communicate with STAR-Mo
CONFIGURATION 31 4.6 POWERSCAN™ M8300/STAR-SYSTEM™ SETUP The following procedure allows configuring a PowerScan™ M8300 reader to communicate with
POWERSCAN™ D8330/M8300 32 6. Set Radio Address ÌRF8Î + four digits from the Numeric Table in the range 0000-1999. ALL READERS MUST HAVE DIFFERENT
CONFIGURATION 33 4.7 BC-8060 STAR-SYSTEM™ NETWORK SETUP When the BC-8060 cradle model is used in an RS-485 network, it must be initially configure
POWERSCAN™ D8330/M8300 34 5. Read the BC-8060 restore default code: Restore BC-8060 Default Ì$+RX0$-qÎ 6. Read the desired Enable Network code
CONFIGURATION 35 4.8 INTERFACE SELECTION Read the interface selection code for your application. RS-232 Standard Ì$+CP0$-$Î POS TERMINALS
POWERSCAN™ D8330/M8300 36 WEDGE IBM AT or PS/2 PCs Ì$+CP500$-aÎ IBM XT PC Notebook Ì$+CP503$-vÎ Ì$+CP505$-ÈÎ IBM SURE1 IBM Terminal 3153
CONFIGURATION 37 WEDGE (CONTINUED) ALT MODE The ALT-mode selection allows barcodes sent to the PC to be interpreted correctly independently from t
Technical SupportFor technical support in North America:Call Toll free: +1 800 387 8898 Option 3, or Direct Dial: +1 905 813 9900 Ext. 1999 Option 3.F
POWERSCAN™ D8330/M8300 38 4.9 USB READER CONFIGURATION The USB interface is available for PowerScan™ D8330, BC-80x0 and C-8000 devices and is compa
CONFIGURATION 39 USB USB-KBD Ì$+UA03$-:Î USB-KBD-ALT-MODE Ì$+UA04$-@Î USB-KBD-APPLE Ì$+UA05$-FÎ USB-COM* Ì$+UA02$-4Î USB-IBM-Table Top
POWERSCAN™ D8330/M8300 40 4.10 CHANGING DEFAULT SETTINGS Once your reader is setup, you can change the default parameters to meet your applicati
41 RS-232 PARAMETERS All PowerScan™ D8330 Series readers + PowerScan™ M8300/BC-80X0 configurations only Baud Rate Parity Data Bits Stop
Enter Configuration Exit and Save Ì$+;Î RS-232 Ì$-?Î 42 BAUD RATE 300 baud ÌCD1XÎ 600 baud 1200 baud ÌCD2[Î ÌCD3^Î 2400 baud 4800
Enter Configuration Exit and Save Ì$+;Î RS-232 Ì$-?Î 43 DATA BITS 7 bits ÌCA0OÎ 8 bits 9 bits ÌCA1RÎ ÌCA2UÎ STOP BITS 1 stop bit ÌCB
Enter Configuration Exit and Save Ì$+;Î RS-232 Ì$-?Î 44 ACK/NACK PROTOCOL disable ÌER0sÎ enable ÌER1vÎ See section 5.1.2 for details,
Enter Configuration Exit and Save Ì$+;Î RS-232 Ì$-?Î 45 RX TIMEOUT timeout control in reception from Host ÌCL5Î Read 2 numbers from the table whe
46 USB PARAMETERS USB-COMHandshaking, Ack/Nack protocol, FIFO, Inter-character delay, Rx timeout, Serial trigger lock USB-KBDKeyboard natio
Enter Configuration Exit and Save Ì$+;Î USB-COM Ì$-?Î 47 HANDSHAKING disable ÌCE0WÎ hardware (RTS/CTS) software (XON/XOFF) ÌCE1ZÎ ÌCE2]Î
Enter Configuration Exit and Save Ì$+;Î USB-COM Ì$-?Î 48 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbe
Enter ConfiguratioN Exit and Save Ì$+;Î USB-KBD Ì$-?Î 49 KEYBOARD NATIONALITY Not Available for USB-KBD-ALT-MODE Interface This parameter default v
Enter Configuration Exit and Save Ì$+;Î USB-KBD Ì$-?Î 50 The Japanese and Eastern Block Keyboard Nationality selections are valid only for IBM AT
Enter ConfiguratioN Exit and Save Ì$+;Î USB-KBD Ì$-?Î 51 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers
52 WEDGE PARAMETERS All PowerScan™D8330 Series readers+ PowerScan™ M8300/BC-80X0 configurations only Keyboard Nationality Caps Lock Caps L
Enter Configuration Exit and Save Ì$+;Î WEDGE Ì$-?Î 53 KEYBOARD NATIONALITY Belgian ÌFJ7yÎ English (UK) French ÌFJ4pÎ ÌFJ2jÎ German Itali
Enter Configuration Exit and Save Ì$+;Î WEDGE Ì$-?Î 54 The Japanese and Eastern Block Keyboard Nationality selections are valid only for IBM AT co
Enter Configuration Exit and Save Ì$+;Î WEDGE Ì$-?Î 55 CAPS LOCK AUTO-RECOGNITION (IBM AT COMPATIBLE ONLY) disable ÌFP0pÎ enable ÌFP1sÎ NU
Enter Configuration Exit and Save Ì$+;Î WEDGE Ì$-?Î 56 INTER-CODE DELAY delay between codes transmitted to Host ÌFG.Î Read 2 numbers from the ta
Enter Configuration Exit and Save Ì$+;Î WEDGE Ì$-?Î 57 Some ASCII characters may be missing, depending on the keyboard type. These are generally pa
TABLE OF CONTENTS i CONTENTS 1 INTRODUCTION ...
58 PEN EMULATION All PowerScan™ D8330 Series readers + PowerScan™ M8300/BC-80X0 configurations only Operating Mode Minimum Output Pulse Co
PEN EMULATION 59 The following operating mode parameters are complete commands and do not require reading the Enter and Exit configuration code
Enter Configuration Exit and Save Ì$+;Î PEN EMULATION Ì$-?Î 60 MINIMUM OUTPUT PULSE 200 s low resolution code emulation high resolution co
Enter Configuration Exit and Save Connfiguration Ì$+;Î PEN EMULATION Ì$-?Î 61 CONVERSION TO CODE 39 (D8330 SERIES ONLY) disable conversion to Co
Enter Configuration Exit and Save Ì$+;Î PEN EMULATION Ì$-?Î 62 OUTPUT LEVEL normal ÌDD0VÎ (white = logic level 0) inverted ÌDD1YÎ (white =
63 NETWORK PARAMETERS BC-8060 model configurations only RS-485 Network Network Baud Rate Slave Address Range Network Warning Message Rece
Enter Configuration Exit and Save Ì$+;Î NETWORK PARAMETERS Ì$-?Î 64 RS-485 NETWORK disable RS-485 network ÌRZ0)Î enable RS-485 slave enab
Enter Configuration Exit and Save Ì$+;Î NETWORK PARAMETERS Ì$-?Î 65 SLAVE ADDRESS RANGE First Address ÌJB(Î Read the code above and the four-digi
Enter Configuration Exit and Save Ì$+;Î NETWORK PARAMETERS Ì$-?Î 66 MASTER CRADLE HEADER no header ÌJA00/Î one character header two cha
Enter Configuration Exit and Save Ì$+;Î NETWORK PARAMETERS Ì$-?Î 67 MASTER CRADLE TERMINATOR no terminator ÌJA102Î one character terminator
POWERSCAN™ D8330/M8300 ii 4.5.1 Using Multiple M-Series Readers with the Same Cradle ... 29 4.5.2 PowerScan™ M8300/STAR-Mo
68 DATA FORMAT NOT FOR PEN INTERFACES Code Identifier Custom Code Identifier Header Terminator Special Keys Field Adjustment Fiel
DATA FORMAT 69 CODE IDENTIFIER TABLE CODE AIM STANDARD MANUFACTURER STANDARD Custom 2/5 interleaved ] I y N 2/5 industrial ] X y P 2/5 n
Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 70 CODE IDENTIFIER disable ÌEB0SÎ Manufacturer standard AIM standard ÌEB1VÎ ÌEB
Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 71 HEADER no header ÌEA00*Î one character header two character header ÌEA01.Î
Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 72 TERMINATOR no terminator ÌEA10-Î one character terminator two character ter
Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 73 SPECIAL KEYS Available only for Wedge IBM AT-PS/2 and USB-KBD Interfaces It is nece
Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 74 FIELD ADJUSTMENT disable field adjustment ÌEF0[Î Field adjustment allows a number
Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 75 FIELD ADJUSTMENT CHARACTER Read the field adjustment character code: field adjust
Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 76 CHARACTER REPLACEMENT disable character replacement ÌEO0mÎ This parameter allows
Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 77 Example: The following strings define: 1. First Character Replacement: substitution in
TABLE OF CONTENTS iii 5.4.6 Time Stamping Delimiter ... 154 5.5 Powe
Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 78 ADDRESS STAMPING (M8300 SERIES ONLY) disable reader address stamping ÌRU0ÊÎ
Enter Configuration Exit and Save Ì$+;Î DATA FORMAT Ì$-?Î 79 TIME STAMPING (M8300 SERIES ONLY) disable ÌIL0kÎ hour/minutes/seconds month/day/
80 POWER SAVE Sleep State Enter Sleep Timeout Read the Enter Configuration code ONCE, available at the top of each page.
Enter Configuration Exit and Save Ì$+;Î POWER SAVE Ì$-?Î 81 SLEEP STATE disable ÌBQ0nÎ enable ÌBQ1qÎ See section 5.5.1 for details. For M8
82 READING PARAMETERS Trigger Type Trigger Signal Trigger Click Trigger-off Timeout Flash Mode Reads per Cycle Safety Time Beeper
Enter Configuration Exit and Save Ì$+;Î READING PARAMETERS Ì$-?Î 83 TRIGGER TYPE hardware trigger ÌBK1eÎ Restores TRIGGER MODE software trigge
Enter Configuration Exit and Save Ì$+;Î READING PARAMETERS Ì$-?Î 84 TRIGGER-OFF TIMEOUT trigger-off timeout ÌBD$Î Read 2 numbers in the range 0
Enter Configuration Exit and Save Ì$+;Î READING PARAMETERS Ì$-?Î 85 SAFETY TIME safety time ÌBE&Î Limits same code consecutive reading. Read
Enter Configuration Exit and Save Ì$+;Î READING PARAMETERS Ì$-?Î 86 BEEPER TONE tone 1 ÌBH0\Î tone 2 tone 3 ÌBH1_Î ÌBH2bÎ tone 4 ÌBH3e
Enter Configuration Exit and Save Ì$+;Î READING PARAMETERS Ì$-?Î 87 GOOD READ SPOT DURATION disable ÌBV0xÎ short medium ÌBV1{Î ÌBV2~Î