Psion PowerScan M8300 series Manuel d'utilisateur Page 178

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 216
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 177
POWERSCAN™ D8330/M8300
166
5.14 CONFIGURATION COPYING COMMANDS
5.14.1 Copy PowerScan D8330 Series
Procedure:
Connect the master (correctly configured reader) and the slave (reader to be
configured) together through two RS-232 serial interface cables and external
power supply. Accessory cables and power supply are available from your Psion
distributor to provide this connection.
RS-232 Cables: CAB471 & CAB472
Power Supply: PG5
Using the slave reader, read the Restore Default barcode and then the RS-232
interface barcode from chapter 4 of this manual or from the Quick Reference
Guide.
With the master reader, read the Configuration Copy barcode below.
Copy Configuration
Ì$+ZZ0$-*Î
The configuration will be copied from the master to the slave reader. The slave
reader signals the end of the procedure with a series of beeps.
NOTE: The master reader can be configured for any interface.
Vue de la page 177
1 2 ... 173 174 175 176 177 178 179 180 181 182 183 ... 215 216

Commentaires sur ces manuels

Pas de commentaire