The message is sent in the following format:
"Message" CR LF
5.3.3 Reception Warning Message
The Master cradle can transmit warning messages to the Host regarding wrong
reception of data.
Example:
/*Two-Ways Out of Sequence!(.....)*/
This message is transmitted to the Host by the Master cradle when the Master cradle
receives a closing string from the Host for a Two-way tx communication, but this was
either not open or already closed, therefore the data will be lost. See section 5.9.4.
5.3.4 Master Header/Terminator Selection
In addition to the standard header/terminator selection, the Master cradle can add its
own header/terminator to the entire message sent to the Host.
In the STAR-System™ network headers and terminators for all RF Devices are
disabled by default.
The Master header and terminator default values are as follows depending on the
interface selection towards the Host:
RS-232: no header, terminator CR-LF
WEDGE: no header, terminator ENTER
See sections 5.4.1 and 5.4.2.